Coaguchek xs manual error 6

Coaguchek error manual

Add: vajaguv36 - Date: 2020-12-11 23:37:59 - Views: 9886 - Clicks: 2189

The CoaguChek XS System 4 Revision History Manual version Revision date Changes 1. Revision History Manual version Revision date Changes Version 1. To get an accurate time on how long it takes your blood to clot, there are Prothrombin Time (PT) tests like CoaguChek XS PT test strips available for patient use. This CoaguChek XS System User Manual is a comprehensive guide to the meter and test strips.

The CoaguChek XS System measures blood- clotting time using blood from the fingertip. If you see an error message, first try to correct the problem using the solution described below. Get the most out of your CoaguChek XS meter. User Manual This CoaguChek XS System User Manual is a. New document, based on international CoaguChek Pro II manualEN -04. Any questions please contact Los medidores CoaguChek® XS están destinados para su utilización por pacientes, aunque también se utilizan en los centros sanitarios para monitorizar la terapia anticoagulante de sus pacientes. Error: Test Strip. When a blood drop is applied, the meter starts the test and the blood mixes with the ingredients on the test strip.

Cleaning/disinfection recommendations. Solution: Repeat the test using a new test strip and blood taken from a new finger. ; Page 2 Manual version Revision date Changes Version 1. v3 Issue date 07. NOTE: For meters with serial number UP0910000 and lower, sporadically occurring ERROR 6 are generally due to an activation of the system fail safe mechanisms that are designed to prevent the release of wrong measurement results. The results are designed to be precise and delivered in one minute. No part of this document may be reproduced or. The reactive components of this reagent consist of thromboplastin and a peptide substrate.

Protection against infection There is a potential risk of infection. You may see the following error messages while using the CoaguChek®XS Meter. , CoaguChek XS Pro meter or, CoaguChek XS meter, CoaguChek XS PT Controls Lancing device, e. The CoaguChek XS PT Test PST test strip contains a lyophilized reagent (reagent in dried form). Condition is "Used".

Read these passages carefully. If the problem persists, call the Roche Diagnostics Technical Service Center at. 99% of the cases in which an “error 6” message is displayed result from an incorrect measurement process.

Read this entire manual carefully, and refer to it as necessary. ; Page 2 On the packaging, on the type plate of the instrument and in the manual you may encounter the following symbols, shown here with their meaning: Use by Lot number For in vitro diagnostic use This product fulfils the requirements of Directive 98/79/EC on in vitro diagnostic medical devices. 15 6 ERROR MESSAGES WHEN PREPARING TO TEST ADDITIONAL ASSISTANCE. · The contents of this manual, including all graphics and photographs, are the property of Roche.

The test uses fresh capillary whole blood and is intended for patient self-testing only. Monitor Bleeding Issues with Coaguchek XS Test Strips. • Use the meter at a relative coaguchek xs manual error 6 humidity of less than 85%, without condensation. If the ERROR 6 message is displayed repeatedly on your CoaguChek XS meter, immediately contact your treating physician. What is CoaguChek XS PT test strip?

6 Section Head CoaguChek XS System User Manual, version 8. The meter giving a single beep following blood application is your indication that the meter has enough blood and has started analyzing the sample, pull away and leave the meter alone to run the test. Revised to add Rx only statement. For more information about CoaguChek® XS. Page 11: How The System Works How the System Works The CoaguChek XS System includes a meter and CoaguChek XS PT test strips. It is designed to. The video will help you get comfortable with the CoaguChek XS Meter and the testing procedure.

The CoaguChek XS System DVD is for new users of the CoaguChek XS System. 4% of the conventional group were able to maintain their INR values within the therapeutic range," Körfer. · If the ERROR 6 message is displayed repeatedly on your CoaguChek XS meter, immediately contact your treating physician. This program will help you get comfortable with the CoaguChek XS Meter and the testing procedure.

Doctors, nurses or any other medical professionals directly involved in the diagnosis and treatment of patients. At the same time, the meter starts to measure the time. New document 2.

Los medidores CoaguChek® XS Plus y CoaguChek® XS Pro son de uso exclusivo por profesionales sanitarios. Page 15 4 alkali-manganese batteries, 1. 5 V, type AAA • USB cable • CoaguChek XS Softclix lancing device with instructions for use • CoaguChek Softclix Lancet • System carry-case (not shown here) • User’s Manual (this document) • Quick Reference Guide CoaguChek INRange User’s Manual.

July 06a Roche CoaguChek XS Plus Error Codes &92;&92;fusafmcf01&92;medicine&92;Cardiac Services&92;iCCnetSA&92;Operations Manual&92;PoCT Instrumentation&92;CoaguChek XS Plus&92; PCT_XSP. The CoaguChek XS System Video is for new users of the CoaguChek XS System. CoaguChek XS Pro Operator’s Manual, version 5. Anticoagulation Medication Anticoagulation medications, also known as blood thinners, are prescribed to avoid unwanted clots. The meter automatically stores the result in memory so that you can easily recall results.

Then, as necessary, refer to the User Manual: The CoaguChek XS System User Manual is a comprehensive guide to the meter and test strips. Roche CoaguChek XS Error Code IE. Test Strip Package Inserts.

Biomedical researchers, academics, and others engaged in medical research. Please check the test strip and restart the test with the same test strip. Both groups were trained in self-monitoring their coagulation and were given the CoaguChek ® S (predecessor of the CoaguChek ® XS) coagulation monitor. Update cleaning/disinfection, minor revisions Version 2. View online Operation & user’s manual for Roche CoaguChek XS System Personal Care Products or simply click Download button to examine the Roche CoaguChek XS System guidelines offline on your desktop or laptop computer.

CoaguChek ® XS Pro POINT OF CARE TESTING Operator’s Manual CoaguChek ® o POINT OF CARE TESTING nual Running Liquid QC - Quick Reference Guide 1. In as new condition. The CoaguChek XS PT Test PST is an in-vitro assay for the determination of prothrombin time (PT) using the CoaguChek INRange meter.

How to correct CoaguChek error messages? Intended use The CoaguChek® Pro II system (consisting of the CoaguChek Pro II meter and the CoaguChek family of test strips) is used for the determination of PT and aPTT by healthcare professionals in a Point of Care environment. I borrowed the machine from the Hughes Foundation and got my strips on prescription. It is designed to provide answers to your questions about the meter’s operation and use.

Patients and caregivers. Important information regarding use Read this operator&39;s manual, as well as the package. Hi, I&39;&39;ve been self testing my INR for about a month. Be sure not to touch or remove the test strip coaguchek while a test is in progress. The CoaguChek XS PT test strip contains various ingredients.

"According to the interim results we now have, 72% of the low-dosage group and 74. Page 10: How The System Works How the System Works The CoaguChek XS System includes a meter and CoaguChek XS PT test strips. Page 1 P O I N T C A R E T E S T I N G CoaguChek XS Plus ® Operator’s Manual. When a sample is applied, thromboplastin activates coagulation, which leads to the formation of thrombin. CoaguChek XS Softclix® Lancets (CoaguChek Softclix Lancet or Accu‑Chek® Safe‑T‑Pro Plus) The CoaguChek XS Softclix lancing device has been specifically developed for self-. 4 Implementation Date: 5:42:04 PM. Important safety instructions and additional information This section explains how safety-related messages and information related to the proper handling of the system are presented in the CoaguChek XS Pro Operator’s Manual. More Coaguchek Xs Manual Error 6 videos.

Important safety instructions and additional information This section explains how safety-related messages and information related to the proper handling of the system are presented in the CoaguChek XS Plus Operator’s Manual. EC v8 -The barcode on the test strips cannot be read -Power off the meter. The meter displays the result in about a minute.

Page 1 P O I N T C A R E T E S T I N G CoaguChek XS Pro ® Operator’s Manual For meters shipped before January. What is CoaguChek XS system user manual? User Manual This CoaguChek XS System User Manual xs is a.

The CoaguChek XS PT Test Strip package insert; the online version of the CoaguChek XS PST system user s manual; and the CoaguChek XS systems are being updated to provide additional ERROR 6 message information and actions. · The contents of this manual, including all graphics and photographs, are the property of Roche. Comes with all manuals coaguchek xs manual error 6 etc. Sent with Australia Post Standard. New document Version 2.

I&39;ve managed some successful coaguchek xs manual error 6 finger prick tests but 2 out of. This is a great video to show all our customers of how to use the CoaguChek for INR monitoring. CoaguChek XS Plus Operator’s Manual, version 9. Getting Started The Getting Started guide shows you how to perform your first coagulation test on the CoaguChek XS Meter. Learn how to avoid potential power issues by watching this short video! The CoaguChek® XS instrument continues to effectively measure your INR values – even if you are receiving antibiotic treatment or chemotherapy. The CoaguChek XS System uses fresh capillary or nonanticoagulated venous whole blood. Medical staff using the CoaguChek XS Plus System to perform tests in more than one patient must be aware that any object coming into contact with human blood is a potential source of infection.

Is CoaguChek XS plus safe? 0 USA Operating Conditions To ensure that the CoaguChek XS Meter functions correctly, follow these guidelines: • Use the meter at room temperature, between coaguchek xs manual error 6 59°F and 90°F (15°C and 32°C).

Coaguchek xs manual error 6

email: dinabuk@gmail.com - phone:(796) 332-9841 x 3149

Novatel mifi 6620l user manual - Manuale audi

-> Manual de traduccion de jeroglificos egipcios pdf
-> Baixar manual da geladeira consul facilite 342 litros

Coaguchek xs manual error 6 - Manual explorist magellan


Sitemap 1

Farming usa 2 instruction manual - Balanced weakly stata manual